  10 watt, wall mount single outputs of 3.3vdc to 55vdc 80-275vac input operating range 4000vac input to output isolation 4 input plug options ul60601-1 3rd edition approvals all specifcations are typical at nominal input, full load, and 25c unless other - wise noted model number output vdc output amps (max.) output power effciency fl, 230vac ripple & noise total regulation no load consumption single output *ahp1001 (a, b, c, or d)-01 3.3 1.82 6 watts 65% typ. 66 mv p-p 5% 0.2 watts *ahp1001 (a, b, c, or d)-02 5 1.6 8 watts 80% typ. 50 mv p-p 5% 0.3 watts *ahp1001 (a, b, c, or d)-03 6 1.33 8 watts 81% typ. 60 mv p-p 5% 0.3 watts *ahp1001 (a, b, c, or d)-04 10 1.0 10 watts 83% typ. 80 mv p-p 5% 0.3 watts *ahp1001 (a, b, c, or d)-05 12 0.83 10 watts 84% typ. 100 mv p-p 5% 0.3 watts *ahp1001 (a, b, c, or d)-06 15 0.66 10 watts 85% typ. 100 mv p-p 5% 0.3 watts *ahp1001 (a, b, c, or d)-07 18 0.55 10 watts 86% typ. 100 mv p-p 5% 0.3 watts *ahp1001 (a, b, c, or d)-08 24 0.42 10 watts 86% typ. 100 mv p-p 5% 0.3 watts *ahp1001 (a, b, c, or d)-09 30 0.33 10 watts 86% typ. 100 mv p-p 3% 0.3 watts *ahp1001 (a, b, c, or d)-10 36 0.27 10 watts 86% typ. 100 mv p-p 3% 0.3 watts *ahp1001 (a, b, c, or d)-11 48 0.21 10 watts 86% typ. 100 mv p-p 3% 0.3 watts *ahp1001 (a, b, c, or d)-12 55 0.18 10 watts 86% typ. 100 mv p-p 3% 0.3 watts option a option d option b option c * note: the asterisk ( * ) denotes a choice of ac input connectors (a, b, c, or d option; i.e. ahp1001b-101). the options are as follows: a: 2 prong u.s. plug in a slimeline package (good for use in space defcient power strips!) b: 3 prong uk plug c: 2 prong euro plug d: 2 prong u.s. plug in a wallmount package please see mechanical dimensions. medical hpu63bseries 63wexternalmedicalgradepowersupply thehpu63bseriesofac/dcswitchingmodepowersupplies provide63wattsofcontinuousoutputpower.allsuppliesare ul94v-1mincompliant.all modelsmeetfccpart-18classband cispr-11en55011classbemissionlimitsandaredesignedto complywithansi/aamies60601-1:2005(ul/cul3rd edition),en 60601-1:2006(tuv/t-mark3rdedition)andnewcerequirements. allunitsare100%burnedinandtested. features: applications: generalspecification: *wideoperatingvoltage,80to275vac,47to63hz *iec-320-c8inputinlet *singleoutput *overvoltageandoverloadprotection *medicalsafety3rd(iec60601-13rdedition) *inputtooutput:2mopp *energystar2.0,efficiencylevelv *classiisystem *3yearwarranty *homehealthcareequipment *patientmonitor *bloodpressuresystem *portablemedicaldevices *ecgmachine * :autorecovery * :freeairconvection * :ul94v-1 * :doubleinsulated,classii :ansi/aamies60601-1:2005(ul/cul3rdedition),en60601-1:2006 (tuv/t-mark3rdedition) shortcircuitprotection cooling flammabilityrating protectionclasses *safety electricalcharacteristics: environmental: symbol characteristic condition min. typ. max. unit vac class vac vac hz w a a a a % %/c c rh rh kv kv kv h m g c % ms ms s symbol characteristic condition min. typ. max. unit vins safetyapprovalinputvoltagerange safetyapproval&specificationinlabel vin inputoperatevoltagerange inputfrequency detailtoseefig.1 (deratelinearlyfrom100%loadat90vacto80%loadat80vac) fi sinewave po outputpowerrange seeratingchart iil lowlineinputcurrent fullload,vin=100vac iih highlineinputcurrent fullload,vin=240vac irl lowlineinputinrushcurrent fullload,25c,coolstart,vin=100vac irh highlineinputinrushcurrent fullload,25c,coolstart,vin=240vac efficiency fullload,vin=230vac,detailtoseeratingchart voi lineregulation fullload,vin=100~120vacor200~240vac olp overloadprotection recoversautomaticallyafterfaultconditionisremoved ttr timeoftransientresponse fullload,vin=110vac thu hold-uptime fullload,vin=100vac ts start-uptime fullload,vin=100~240vac tc temperaturecoefficient allcondition hv dielectricwithstandingvoltage(p-s) primarytosecondary,limitcurrent<10ma emi to ts ho hs vsg esda esdc mtbf elev vbr emcemission compliancetoen55011(cispr11),en61000-3-2,-3 100 80 47 63 63 1.62 0.72 37 74 seeratingchart 110 12 0.3 4000 -10 0 0 2 8 6 100k 5 -40 b 150 70 85 95% 95% 3000 4 2 0.04 1 240 275 operatingtemperature storagetemperature operatinghumidity storagehumidity surgevoltage electrostaticdischarge electrostaticdischarge meantimebetweenfailure operatingaltitude(elevation) vibration detailtoseefig.2 (deratelinearlyfrom100%loadat40cto50%loadat70c) 10~95%rh non-condensing seeratingchart allcondition airdischarge,iec61000-4-2 contactdischarge,iec61000-4-2 operatingtemperatureat25c,calculatedpermil-hdbk-217f allcondition 10~500hz,10min./1cycle,60min.eachalongx,y,zaxes rohs 2011/65/eu 2 cb en 60601-1 iec 60601-1 s e p approvals: % ovp 112 132 overvoltageprotection medical grade class ii 10 watt adapter ahp1001 series www.astrodynetdi.com astrodyne usa: 1-800-823-8082 astrodyne pacific: 886-2-26983458
* these are stress ratings. exposure of the devices to any of these conditions may adversely affect long term reliability. proper operation under conditions other than the standard operating conditions is neither warranteed nor implied. input specifications input voltage range (see i/p 80-275 vac (100-240vac nom.) see input derate curve (fig 1) frequency range sine wave, 47-63 hz inrush i, cold start, fl 25c 40a @ 100vac * 100a @ 240vac fl * input current (100vin/240vin) 0.3a max./0.2a max. fl protection class double insulated, class ii output specifications voltage and current see selection chart page 1 line regulation hl-ll 1%, max. fl total regulation see selection chart page 1 ripple/noise (see note) see selection chart page 1 over load protection 110-150% max. auto recovery * short circuit protection auto recovery * transient response 4ms at fl, 110vac start up time 2s, min. at fl, 100vac hold up time 12ms, min. at fl, 100vac temperature coeffcient 0.04%/c physical specifications size l x w x h (inches/mm) 2.2 x 1.73 x 1.08 / 56 x 44 x 27.5mm weight 90g typ. environmental specifications operating temperature -10 to +70c see temp derate curve (fig 2) storage temperature -40 to +85c, 10~95% rh * operating & storage humidity 0% to +95%, non-condensing * cooling free air convection surge voltage 2kv, min. emc emission en55011 (cispr11) en61000-3-2, -3 class b esd contact 6kv, air 8kv iec61000-4-2 vibration 5g min. operating altitude (elevation) 3000m max. 10 ~ 500hz, 10min./1cycle, 60min. each along x, y, z axes mtbf 100,000 hrs, min. mil-hdbk-217f, 25c flammability rating ul94v-1 general specifications isolation i/p-o/p: 4000vac limit current <10ma o/p-ground: 707vdc 60s insulation resistance 20m, 500v, 1s, i/p to o/p effciency at fl & nominal line see selection chart safety ul/cul: ansi/aami es60601- 1:2005 3rd ed. note ripple & noise is measured by using a 20mhz bandwidth limited oscilloscope and terminating each output with a 0.47uf capacitor at fl and nominal line. medical grade class ii 10 watt adapter ahp1001 series www.astrodynetdi.com astrodyne usa: 1-800-823-8082 astrodyne pacific: 886-2-26983458
mechanical dimensions medical hpu10aseries specificationnote: 1.outputcanprovideuptopeakloadwhenthepowersupplystartsup. continuousstayinginmorethanratedloadisnotallowed. 2.atfactory,in60%ratedloadcondition,eachoutputischeckedtobe withinvoltageaccuracy. 3.lineregulationisdefinedbychanging10%ofinputvoltagefrom nominallineatratedload. 4.loadregulationisdefinedbychanging40%ofmeasuredoutputload from60%ratedload. 5.ripple&noiseismeasuredbyusing20mhzbandwidthlimited oscilloscopeandterminatedeachoutputwitha0.47ufcapacitorat ratedloadandnominalline. 6.holduptimeismeasuredfromtheendofthelastchargingpulsetothe timewhichthemainoutputdropsdowntolowlimitofmainoutputat ratedloadandnominalline. 7.efficiencyismeasuredatratedload,andnominalline. 8.thespecificsfortestingtheenergyefficiencyofthisseriesareoutlined inaseparatedocumenttitled"testmethodforcalculatingtheenergy efficiencyofsingle-voltageinterchangeableac-dcandac-acpower supplies(august11,2004),"whichisavailableontheenergystar website. mechanicaldimensions: (unit:mm) outputcablerecommend: packing: 1.selectedoutputconnectorsandwire,pleaserefertoappendix. 2.hpu10a-101~105arerequiredtouseawg#20/4ftoutputcable. 3.hpu10a-106~112arerequiredtouseawg#24/4ftoutputcable. 4.theregulationandefficiencywillbechangedbymodifiedoutputcable . 1.netweight:90gapprox. 2.optionaloutputconnectorsavailablecontactsalesfordetails. ratingchart: inputvoltage(vac) load(%) 80 50 60 70 80 90 100 110 100 120 140 160 180 200 220 240 260 280 (fig.1)inputvoltagederatingcurve modelno. adjustable voltagerange min (vdc) (vdc) (a) (a) (w) (w) (ms) (mvp-p) (%) (%) min max max adjustmentmaximum outputcurrent (basedontheoutputvolt.) maximum outputpower ripple&noise totalregulation typ.efficiency noload consumption hold-uptime protectionmode hpu10a-101 hpu10a-102 3.0 5.0 5.0 6.0 1.20 1.33 2.00 1.60 6 8 66 50 65 80 0.2 0.3 12 12 12 12 12 12 12 12 12 12 12 12 olp olp olp olp olp olp olp olp olp olp olp olp 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 81 83 84 85 86 86 86 86 86 86 5 5 5 5 5 5 5 5 3 3 3 3 60 80 100 100 100 100 100 100 100 100 8 10 10 10 10 10 10 10 10 10 1.33 1.25 0.90 0.76 0.62 0.47 0.37 0.30 0.25 0.20 1.00 0.90 0.76 0.62 0.47 0.37 0.30 0.25 0.20 0.19 8.0 11.0 13.0 6.0 8.0 11.0 13.0 16.0 16.0 21.0 27.0 33.0 40.0 50.0 21.0 27.0 33.0 40.0 50.0 55.0 hpu10a-103 hpu10a-104 hpu10a-105 hpu10a-106 hpu10a-107 hpu10a-108 hpu10a-109 hpu10a-110 hpu10a-111 hpu10a-112 10wexternalmedicalgradepowersupply temperature(c) -10 0 10 0 10 20 30 40 50 60 70 80 90 100 110 20 30 40 50 60 70 80 (fig.2)temperaturederatingcurve medical hpu10bseries specificationnote: 1.outputcanprovideuptopeakloadwhenthepowersupplystartsup. continuousstayinginmorethanratedloadisnotallowed. 2.atfactory,in60%ratedloadcondition,eachoutputischeckedtobe withinvoltageaccuracy. 3.lineregulationisdefinedbychanging10%ofinputvoltagefrom nominallineatratedload. 4.loadregulationisdefinedbychanging40%ofmeasuredoutputload from60%ratedload. 5.ripple&noiseismeasuredbyusing20mhzbandwidthlimited oscilloscopeandterminatedeachoutputwitha0.47ufcapacitorat ratedloadandnominalline. 6.holduptimeismeasuredfromtheendofthelastchargingpulsetothe timewhichthemainoutputdropsdowntolowlimitofmainoutputat ratedloadandnominalline. 7.efficiencyismeasuredatratedload,andnominalline. 8.thespecificsfortestingtheenergyefficiencyofthisseriesareoutlined inaseparatedocumenttitled"testmethodforcalculatingtheenergy efficiencyofsingle-voltageinterchangeableac-dcandac-acpower supplies(august11,2004),"whichisavailableontheenergystar website. mechanicaldimensions: (unit:mm) outputcablerecommend: packing: 1.selectedoutputconnectorsandwire,pleaserefertoappendix. 2.hpu10b-101~105arerequiredtouseawg#20/4ftoutputcable. 3.hpu10b-106~112arerequiredtouseawg#24/4ftoutputcable. 4.theregulationandefficiencywillbechangedbymodifiedoutputcable . 1.netweight:90gapprox. 2.optionaloutputconnectorsavailablecontactsalesfordetails. ratingchart: inputvoltage(vac) load(%) 80 50 60 70 80 90 100 110 100 120 140 160 180 200 220 240 260 280 (fig.1)inputvoltagederatingcurve modelno. adjustable voltagerange min (vdc) (vdc) (a) (a) (w) (w) (ms) (mvp-p) (%) (%) min max max adjustmentmaximum outputcurrent (basedontheoutputvolt.) maximum outputpower ripple&noise totalregulation typ.efficiency noload consumption hold-uptime protectionmode hpu10b-101 hpu10b-102 3.0 5.0 5.0 6.0 1.20 1.33 2.00 1.60 6 8 66 50 65 80 0.2 0.3 12 12 12 12 12 12 12 12 12 12 12 12 olp olp olp olp olp olp olp olp olp olp olp olp 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 81 83 84 85 86 86 86 86 86 86 5 5 5 5 5 5 5 5 3 3 3 3 60 80 100 100 100 100 100 100 100 100 8 10 10 10 10 10 10 10 10 10 1.33 1.25 0.90 0.76 0.62 0.47 0.37 0.30 0.25 0.20 1.00 0.90 0.76 0.62 0.47 0.37 0.30 0.25 0.20 0.19 8.0 11.0 13.0 6.0 8.0 11.0 13.0 16.0 16.0 21.0 27.0 33.0 40.0 50.0 21.0 27.0 33.0 40.0 50.0 55.0 hpu10b-103 hpu10b-104 hpu10b-105 hpu10b-106 hpu10b-107 hpu10b-108 hpu10b-109 hpu10b-110 hpu10b-111 hpu10b-112 10wexternalmedicalgradepowersupply temperature(c) -10 0 10 0 10 20 30 40 50 60 70 80 90 100 110 20 30 40 50 60 70 80 (fig.2)temperaturederatingcurve caution medical hpu10cseries specificationnote: 1.outputcanprovideuptopeakloadwhenthepowersupplystartsup. continuousstayinginmorethanratedloadisnotallowed. 2.atfactory,in60%ratedloadcondition,eachoutputischeckedtobe withinvoltageaccuracy. 3.lineregulationisdefinedbychanging10%ofinputvoltagefrom nominallineatratedload. 4.loadregulationisdefinedbychanging40%ofmeasuredoutputload from60%ratedload. 5.ripple&noiseismeasuredbyusing20mhzbandwidthlimited oscilloscopeandterminatedeachoutputwitha0.47ufcapacitorat ratedloadandnominalline. 6.holduptimeismeasuredfromtheendofthelastchargingpulsetothe timewhichthemainoutputdropsdowntolowlimitofmainoutputat ratedloadandnominalline. 7.efficiencyismeasuredatratedload,andnominalline. 8.thespecificsfortestingtheenergyefficiencyofthisseriesareoutlined inaseparatedocumenttitled"testmethodforcalculatingtheenergy efficiencyofsingle-voltageinterchangeableac-dcandac-acpower supplies(august11,2004),"whichisavailableontheenergystar website. mechanicaldimensions: (unit:mm) outputcablerecommend: packing: 1.selectedoutputconnectorsandwire,pleaserefertoappendix. 2.hpu10c-101~105arerequiredtouseawg#20/4ftoutputcable. 3.hpu10c-106~112arerequiredtouseawg#24/4ftoutputcable. 4.theregulationandefficiencywillbechangedbymodifiedoutputcable . 1.netweight:90gapprox. 2.optionaloutputconnectorsavailablecontactsalesfordetails. ratingchart: inputvoltage(vac) load(%) 80 50 60 70 80 90 100 110 100 120 140 160 180 200 220 240 260 280 (fig.1)inputvoltagederatingcurve modelno. adjustable voltagerange min (vdc) (vdc) (a) (a) (w) (w) (ms) (mvp-p) (%) (%) min max max adjustmentmaximum outputcurrent (basedontheoutputvolt.) maximum outputpower ripple&noise totalregulation typ.efficiency noload consumption hold-uptime protectionmode hpu10c-101 hpu10c-102 3.0 5.0 5.0 6.0 1.20 1.33 2.00 1.60 6 8 66 50 65 80 0.2 0.3 12 12 12 12 12 12 12 12 12 12 12 12 olp olp olp olp olp olp olp olp olp olp olp olp 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 81 83 84 85 86 86 86 86 86 86 5 5 5 5 5 5 5 5 3 3 3 3 60 80 100 100 100 100 100 100 100 100 8 10 10 10 10 10 10 10 10 10 1.33 1.25 0.90 0.76 0.62 0.47 0.37 0.30 0.25 0.20 1.00 0.90 0.76 0.62 0.47 0.37 0.30 0.25 0.20 0.19 8.0 11.0 13.0 6.0 8.0 11.0 13.0 16.0 16.0 21.0 27.0 33.0 40.0 50.0 21.0 27.0 33.0 40.0 50.0 55.0 hpu10c-103 hpu10c-104 hpu10c-105 hpu10c-106 hpu10c-107 hpu10c-108 hpu10c-109 hpu10c-110 hpu10c-111 hpu10c-112 10wexternalmedicalgradepowersupply temperature(c) -10 0 10 0 10 20 30 40 50 60 70 80 90 100 110 20 30 40 50 60 70 80 (fig.2)temperaturederatingcurve c a u ti o n medical hpu10dseries specificationnote: 1.outputcanprovideuptopeakloadwhenthepowersupplystartsup. continuousstayinginmorethanratedloadisnotallowed. 2.atfactory,in60%ratedloadcondition,eachoutputischeckedtobe withinvoltageaccuracy. 3.lineregulationisdefinedbychanging10%ofinputvoltagefrom nominallineatratedload. 4.loadregulationisdefinedbychanging40%ofmeasuredoutputload from60%ratedload. 5.ripple&noiseismeasuredbyusing20mhzbandwidthlimited oscilloscopeandterminatedeachoutputwitha0.47ufcapacitorat ratedloadandnominalline. 6.holduptimeismeasuredfromtheendofthelastchargingpulsetothe timewhichthemainoutputdropsdowntolowlimitofmainoutputat ratedloadandnominalline. 7.efficiencyismeasuredatratedload,andnominalline. 8.thespecificsfortestingtheenergyefficiencyofthisseriesareoutlined inaseparatedocumenttitled"testmethodforcalculatingtheenergy efficiencyofsingle-voltageinterchangeableac-dcandac-acpower supplies(august11,2004),"whichisavailableontheenergystar website. mechanicaldimensions: (unit:mm) outputcablerecommend: packing: 1.selectedoutputconnectorsandwire,pleaserefertoappendix. 2.hpu10d-101~105arerequiredtouseawg#20/4ftoutputcable. 3.hpu10d-106~112arerequiredtouseawg#24/4ftoutputcable. 4.theregulationandefficiencywillbechangedbymodifiedoutputcable . 1.netweight:90gapprox. 2.optionaloutputconnectorsavailablecontactsalesfordetails. ratingchart: inputvoltage(vac) load(%) 80 50 60 70 80 90 100 110 100 120 140 160 180 200 220 240 260 280 (fig.1)inputvoltagederatingcurve modelno. adjustable voltagerange min (vdc) (vdc) (a) (a) (w) (w) (ms) (mvp-p) (%) (%) min max max adjustmentmaximum outputcurrent (basedontheoutputvolt.) maximum outputpower ripple&noise totalregulation typ.efficiency noload consumption hold-uptime protectionmode hpu10d-101 hpu10d-102 3.0 5.0 5.0 6.0 1.20 1.33 2.00 1.60 6 8 66 50 65 80 0.2 0.3 12 12 12 12 12 12 12 12 12 12 12 12 olp olp olp olp olp olp olp olp olp olp olp olp 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 81 83 84 85 86 86 86 86 86 86 5 5 5 5 5 5 5 5 3 3 3 3 60 80 100 100 100 100 100 100 100 100 8 10 10 10 10 10 10 10 10 10 1.33 1.25 0.90 0.76 0.62 0.47 0.37 0.30 0.25 0.20 1.00 0.90 0.76 0.62 0.47 0.37 0.30 0.25 0.20 0.19 8.0 11.0 13.0 6.0 8.0 11.0 13.0 16.0 16.0 21.0 27.0 33.0 40.0 50.0 21.0 27.0 33.0 40.0 50.0 55.0 hpu10d-103 hpu10d-104 hpu10d-105 hpu10d-106 hpu10d-107 hpu10d-108 hpu10d-109 hpu10d-110 hpu10d-111 hpu10d-112 10wexternalmedicalgradepowersupply temperature(c) -10 0 10 0 10 20 30 40 50 60 70 80 90 100 110 20 30 40 50 60 70 80 (fig.2)temperaturederatingcurve c a u t i o n ahp1001a ahp1001b ahp1001c ahp1001d dc output connections coaxial plug +vout -vout 5.5mm outer diameter 2.1mm inner diameter, female 11mm length, center + to meet these published specs: ahp1001x-01~05 requires an output cord length of 48 and 20awg wire ahp1001x-06~12 requires an output cord length pf 48 and 24awg wire any deviation from these requirements will change the regulation and effciency of the product medical grade class ii 10 watt adapter ahp1001 series www.astrodynetdi.com astrodyne usa: 1-800-823-8082 astrodyne pacific: 886-2-26983458
derating curves 0315 medical hpu10aseries specificationnote: 1.outputcanprovideuptopeakloadwhenthepowersupplystartsup. continuousstayinginmorethanratedloadisnotallowed. 2.atfactory,in60%ratedloadcondition,eachoutputischeckedtobe withinvoltageaccuracy. 3.lineregulationisdefinedbychanging10%ofinputvoltagefrom nominallineatratedload. 4.loadregulationisdefinedbychanging40%ofmeasuredoutputload from60%ratedload. 5.ripple&noiseismeasuredbyusing20mhzbandwidthlimited oscilloscopeandterminatedeachoutputwitha0.47ufcapacitorat ratedloadandnominalline. 6.holduptimeismeasuredfromtheendofthelastchargingpulsetothe timewhichthemainoutputdropsdowntolowlimitofmainoutputat ratedloadandnominalline. 7.efficiencyismeasuredatratedload,andnominalline. 8.thespecificsfortestingtheenergyefficiencyofthisseriesareoutlined inaseparatedocumenttitled"testmethodforcalculatingtheenergy efficiencyofsingle-voltageinterchangeableac-dcandac-acpower supplies(august11,2004),"whichisavailableontheenergystar website. mechanicaldimensions: (unit:mm) outputcablerecommend: packing: 1.selectedoutputconnectorsandwire,pleaserefertoappendix. 2.hpu10a-101~105arerequiredtouseawg#20/4ftoutputcable. 3.hpu10a-106~112arerequiredtouseawg#24/4ftoutputcable. 4.theregulationandefficiencywillbechangedbymodifiedoutputcable . 1.netweight:90gapprox. 2.optionaloutputconnectorsavailablecontactsalesfordetails. ratingchart: inputvoltage(vac) load(%) 80 50 60 70 80 90 100 110 100 120 140 160 180 200 220 240 260 280 (fig.1)inputvoltagederatingcurve modelno. adjustable voltagerange min (vdc) (vdc) (a) (a) (w) (w) (ms) (mvp-p) (%) (%) min max max adjustmentmaximum outputcurrent (basedontheoutputvolt.) maximum outputpower ripple&noise totalregulation typ.efficiency noload consumption hold-uptime protectionmode hpu10a-101 hpu10a-102 3.0 5.0 5.0 6.0 1.20 1.33 2.00 1.60 6 8 66 50 65 80 0.2 0.3 12 12 12 12 12 12 12 12 12 12 12 12 olp olp olp olp olp olp olp olp olp olp olp olp 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 81 83 84 85 86 86 86 86 86 86 5 5 5 5 5 5 5 5 3 3 3 3 60 80 100 100 100 100 100 100 100 100 8 10 10 10 10 10 10 10 10 10 1.33 1.25 0.90 0.76 0.62 0.47 0.37 0.30 0.25 0.20 1.00 0.90 0.76 0.62 0.47 0.37 0.30 0.25 0.20 0.19 8.0 11.0 13.0 6.0 8.0 11.0 13.0 16.0 16.0 21.0 27.0 33.0 40.0 50.0 21.0 27.0 33.0 40.0 50.0 55.0 hpu10a-103 hpu10a-104 hpu10a-105 hpu10a-106 hpu10a-107 hpu10a-108 hpu10a-109 hpu10a-110 hpu10a-111 hpu10a-112 10wexternalmedicalgradepowersupply 0wuwr01waext wm m wm m wm sm ?m um dm cm gm lm om wmm wwm sm ?m um dm cm gm lm ephiysta0wuwr01wanwr0hpiax1w medical grade class ii 10 watt adapter ahp1001 series www.astrodynetdi.com astrodyne usa: 1-800-823-8082 astrodyne pacific: 886-2-26983458


▲Up To Search▲   

 
Price & Availability of AHP1001-03

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X